Search the Site Index:





Overlay 1

Updated on 4 Mar 2026
1/5   1/6   1/7   1/8   1/9   1/10   1/11   1/12   1/13   1/14   1/15   1/16   1/17   1/18   1/19   1/20   1/21   1/22   1/23   1/24   1/25   1/26   1/27   1/28   1/29   1/30   1/32   1/33   1/34   1/35   1/36   1/38   1/39   1/40   1/41   1/42   1/43   1/44   1/45   1/46   1/47   1/48   1/49   1/50   1/51   1/52   1/53   1/54   1/55   1/56   1/57   1/58   1/59   1/60   1/61   1/62   1/63   1/64   1/65   1/66   1/67   1/68   1/70   1/71   1/72   1/73   1/74   1/75   1/76   1/77   1/78   1/79   1/80   1/81   1/82   1/83   1/84   1/85   1/86   1/87   1/88   1/89   1/90   1/91   1/92   1/93   1/94   1/95   1/96   1/97   1/98   1/99   1/101-104   1/105   1/106   1/107   1/108   1/109   1/110   1/111   1/112   1/113   1/114   1/115   1/116   1/117   1/118   1/119   1/120   1/121   1/122   1/123   1/124   1/125   1/126   1/127   1/128   1/129   1/130   1/131   1/132   1/133   1/135   1/136   1/137   1/138   1/139   1/140   1/141   1/142   1/143   1/144   1/145   1/146   1/147   1/148   1/149   1/150   1/151   1/152   1/153   1/154   1/155   1/156   1/157   1/158   1/159   1/160   1/160   1/161   1/162   1/163   1/164   1/165   1/166   1/167   1/168   1/170   1/171   1/172   1/173   1/174   1/175   1/176   1/177   1/178   1/179   1/180   1/181   1/182   1/183   1/184   1/185   1/186   1/187   1/188   1/190   1/191   1/192   1/193   1/194   1/195   1/196   1/198   1/199   1/200   1/201   1/202   1/203   1/204   1/205   1/206   1/207   1/208

Overlay 1

IOp(1/5)

0 Find local minimum.
1 Find a saddle point.
N Find stationary point on the energy surface with N negative eigenvalues of the 2nd deriv. matrix.
0 Locate the maximum in the LST path.
1 Scan the LST path.
N000 Which approximation to make. Default is III for Tomasi (interlocking spheres) and IV for general surface.
1000 Apprx.   I: Don’t Do Self-Polarization or “Compensation”
2000 Apprx.  II: Do Self-Polarization, But No Compensation.
3000 Apprx. III: Do Self-Polarization and Compensation.
4000 Apprx.  IV: Do III, and Allow Surface To “Relax” in Solution if no spheres…
N0000 Whether to evaluate densities using orbitals or density matrix. Default is to use density.
10000 Use MOs.
20000 Use density.

IOp(1/6)

0 NSTEP = Max(20,NVAR+10) (L103)
  = Min(20,NVAR+10) (L102, L105, L109)
  = Min(40,NVAR+20) (L113, L114)
N NSTEP = N
0 Default = 1 trajectory
N NTraj = N

IOp(1/7)

-1 ConvF = 1/600 Hartree/Bohr or Radian
0 ConvF = 0.0003 Hartree/Bohr or Radian
N ConvF = N*10-6
4 ConvF= (N-3)*10-6, do not terminate job on non-convergence
3 ConvF= 0.0003 HARTREE/BOHR OR RADIAN, do not terminate job on non-convergence
2 ConvF = 1/600 HARTREE/BOHR OR RADIAN, do not terminate job on non-convergence
1 Default value for optimizations: 10-7
0 Default value for single-points: 10-5 in L116, 10-7 in L117
N 10-N

IOp(1/8)

0 DXMAXT = 0.1 Bohr or Radian (L103, Estm or UnitFC).
  = 0.3 Bohr or Radian (L103, Read or CalcFC).
  = 0.2 Bohr or Radian (L105).
  = 0.3 Bohr or Radian(L113, L114).
N DXMAXT = 0.01 * N
0 Which type of basin to use to partition the density isosurface. Default is 4.
1 GradVne.
2 GradRho.
3 Don’t Use Basins, Use only the Center of Nuclear Charge.
4 Use Interlocking Spheres.
N0 Order of Adam’s-Bashforth-Moulton (ABM) predictor-corrector method to use in solving diff. eqns. for the grad RHO or Vne trajectories. Default is 4; max is 9.
N00 Number of small steps per ABM step to be used in starting ABM and when “slow down” is needed in ABM. Default is 5.
N000 Which approximation to make. Default is III for Tomasi (interlocking spheres) and IV for general surface.
1000 Apprx. I – Don’t Do Self-Polarization or “Compensation”
2000 Apprx. II – Do Self-Polarization, But No Compensation.
3000 Apprx. III – Do Self-Polarization and Compensation.
4000 Apprx. IV – Do III, and Allow Surface To “Relax” in Solution if no spheres…
N0000 Whether to evaluate densities using orbitals or density matrix. Default is to use density.
10000 Use MOs.
20000 Use density.
MMM000000 Micro-step size = MMM/10000 fs for propagation on interpolated surface; MMM should be smaller than the regular time step

IOp(1/9)

0 Whether to update trust radius (DXMaxT, default Yes). Default is Yes for minima, no for TS.
1 No.
2 Yes.
00 Whether to scale or search the sphere when reducing the step size to the trust radius. Default search for minima, scale for transition states.
10 Scale.
20 Search.
0 Yes.
1 No.
10 Do not use symmetry to skip steps back.
100 Do not use symmetry to skip equivalent atoms
0 Yes.
1 No.
0 No; Approx. 1.0 D-6 (N=20)
1 Yes, using a default criterion (0.05 Angstroms).
-N Yes, using a (10-N Angstroms) criteria: 2.0-N.
N 2.0-N
0 Default (same as 1).
1 Generate random initial velocity.
2 Read in initial Cartesian velocity (Bohr/sec).
3 Read in initial MW Cartesian velocity (sqrt(amu)*Bohr/sec).

IOp(1/10)

0 Use defaults (not valid for L109).
1 Read ((FC(I,J),J=1,I),I=1,NVAR) (8F10.6) (L103 only).
2 Read I,J,FC(I,J) (5I3,F20.0) (L103 only). End with a blank card.
3 Read from checkpoint file in internal coordinates.
4 Second derivative matrix calculated analytically. (Not valid for L109).
5 Read Cartesian forces and force constants from the checkpoint file are converted to internal coordinates.
6 Read Cartesian forces followed by Cartesian force constants (both in format 6F12.8) from input stream, followed by a blank line.
7 Use semi-empirical force constants.
8 Use unit matrix (default for L105; only recognized by 103).
9 Estimate force constants using valence force field.
10 Use unit matrix throughout.
1xxxxxx L103 should assume L716 has transformed forces.

IOp(1/11)

0 Default (Test for z-matrix or Cartesian TS but not for LST/QST or for minimum).
1 Don’t test.
2 Test.
0 0.05 (N=2).
N 0.1/N.

IOp(1/12)

0 Use default values.
1 Read in new values for all parameters (see INITBS).

IOp(1/13)

0 Default (9 for L103 minimization, 7 for L103 TS, D2Corr and L115, Powell for L113 and L114, Bofill in L123).
1 Powell (not in L103).
2 BFGS (not in L103).
3 BFGS, safeguarding positive definiteness (not in L103 or L115).
4 D2Corr (New, only in L103 and L115).
5 D2Corr (Old, only in L103 and L115).
6 D2Corr (BFGS).
7 D2Corr (Bofill Powell+MS for transition states).
8 D2Corr (No update, use initial Hessian).
9 D2Corr (New if energy rises, otherwise BFGS).
0xx Proceed normally.
1xx Use a modified version of D2Corr with different weights for different types of internal coordinates according to OptDX (currently, 0.1 for dihedral angles and 1.0 for any other type). It works only for old redundant internal coordinates and GICs. Default to 0xx if the method is not D2Corr.
2xx Use a modified version of D2Corr with different weights for different types of internal coordinates according to CrdGRo (changing from 0.1 for nonrigid to 1.0 for rigid coordinates). It works for GICs only. Default to 0xx if the method is not D2Corr.
0 No multi-time stepping.
NN Iterate density constraints NN times per step.
MM00 Do gradient once every MM steps.
0 Default (Bofill).
1 Murtagh-Sargent (SR1) update.
2 Powell-symmetric-Broyden (PSB) update.
3 Bofill’s update.
4 Sqrt(Bofill) update.
5 No update (keep old Hessian).
0 Default: Velocity Verlet (L127)
1 Runge-Kutta Method 4th order (L130)
2 Bulirsch-Stoer Method (L130)
3 Velocity Verlet (L130)
5 Ehrenfest Velocity Verlet (L127)

IOp(1/14)

-1 0.
0 Default (0 for TS, 1 for minima).
N Allow N — linear only starts with the N+1st.

IOp(1/15)

-1 or 0 No force test at all.
N FMAXT = 0.1 * N.

IOp(1/16)

0 EIGMAX = 25.0 Hartree / Bohr2 or Radian2
N EIGMAX = 0.1 * N

IOp(1/17)

0 EIGMIN = 0.0001.
N EIGMIN = 1. / N.

IOp(1/18)

0 Proceed normally.
1 Second derivatives will be computed as directed on the variable definition cards. No optimization will occur.
9 Same as zero.
10 Do optimization in Cartesian coordinates.
20 Do full optimization in redundant internal coordinates.
30 Do full optimization in pruned distance matrix coordinates.
40 Do optimization in z-matrix coordinates.
50 Do full optimization in redundant internal coordinates with large molecular tools.
100 Read the AddRedundant input section for each structure.
1000 Do not define H-bonds (default).
2000 Define H-bonds with no related coordinates.
3000 Define H-bonds and related coordinates.
10000 Reduce the number of redundant internals.
20000 Define all redundant internals.
100000 Old definition of redundant internals.
0000000 Default (2000000).
1000000 Skip MM atoms in internal coordinate definitions and do microiterations the old way, in L103.
2000000 Include MM atoms in internal coordinate definitions (no microiterations).
3000000 Skip MM atoms in internal coordinate definitions and do microiterations the new way, in L120.
4000000 Microiterations for pure MM, done in L402.

IOp(1/19)

0 Default (same as 6).
2 Linear and steepest descent.
3 Steepest descent and linear only when essential.
4 Quadratic if curvature is correct; RFO if not. Linear as usual.
5 Quadratic if curvature is correct; RFO if not. No linear search.
6 RFO and linear.
7 RFO without linear.
8 Newton-Raphson and linear.
9 Newton-Raphson only.
10 GDIIS and linear.
11 GDIIS only.
13 First-order simultaneous optimization.
15 GEDIIS.
17 FOSimult with fixed geometry, for debugging.
19 FOSimult with full SCF convergence, for debugging.
0xxx Default (2)
1xxx Turns on QMMM linear search in l103.
2xxx Turns off QMMM linear search in l103.
0 P-RFO or RFO step only (Default).
1 P-RFO or RFO step for “wrong” Hessian otherwise Newton Raphson.

IOp(1/20)

0 Angstroms degrees.
1 Bohrs degrees.
2 Angstroms Radians.
3 Bohrs Radians.

IOp(1/21)

0 Normal mode.
1 Expert mode. Certain cutoffs used to control the optimization will be relaxed. These include FMAXT, DXMAXT, EIGMAX and EIGMIN.

IOp(1/22)

0 Yes.
1 Assume reactant order equals product order.
2 Read in a re-ordering vector from the input.
0 Both directions and generate search vector.
1 Forward direction and generates vector.
2 Backward direction and generates vector.
3 Both directions and generates vector.
4 Forward direction and reads vector 8F10.6.
5 Forward direction and reads vector 8F10.6.
6 Backward direction and reads vector 8F10.6.
7 Both directions and reads vector 8F10.6.

IOp(1/23)

Harmonic constraints.

0 Default (No unless Geom=AllCheck).
1 Yes, using the initial structure.
2 Yes, reading the initial structure from the chk file.
3 Read in the structure from input.
4 Read in the structure and force constants from input.
5 Use the initial structure and read a list of atoms to constrain.
9 No.
MMMMMMMx    For 1, 3, and 4 use force constant N/10-6 Hartree/Bohr**2. 0 defaults to the previous force constants for 2 and to 0.1/NAtCon otherwise, where NAtCon is the number of atoms constrained.

IOp(1/24)

Whether to round tetrahedral angles.

0 Default (Yes).
1 Yes, round angles within 0.001 degree.
2 No.

IOp(1/25)

Whether SCRF is used with numerical polarizability.

0 No.
1 Yes, the field in /Gen/ must be cleared each time.

IOp(1/26)

Accuracy of function being optimized:

-NNMM Energy 10-NN, Gradient 10-MM.
-1 Read in values.
0 Default (same as 1).
1 Normal accuracy for HF (energy and gradient both 1.d-7).
2 Accuracy for DFT with SG1 grid (Energy 1.d-5, gradient 1.d-4).
3 Fine grid accuracy for DFT (Energy 1.d-7, gradient 1.d-6).
4 Ultrafine accuracy (E 1.d-7, G 1.d-6).
5 Superfine accuracy (E 1.d-7, G 1.d-7).
6 UltraFine+PCM accuracy (E 5.d-5, G 5.d-6)

IOp(1/27)

= IJKL (i.e. 1000*I+100*J+10*K+L).

-1 Read IOp(42) structures and store on general scan file (798) with first structure left in /Mol/.
-2 Add IOp(42) structures to those already on the general scan file and leave the first new structure in /Mol/.
>0 Transition state searching using QST and redundant internal coordinates.
L = 0,1 Input one structure, either initial guess of the minimizing structure or transition structure without QST.
L = 2 Input 2 structures. The first one is the reactant, the second one is the product. The union of the two redundant coordinates is taken as the redundant coordinates for the TS. The values of the TS coordinate are estimated by interpolating the structure of R and P. R and Pare used to guide the QST optimization of the TS.
L = 3 Input 3 structures. The first one is the reactant the second one is the product. The third one is the initial guess of the transition structure. R and P are used to guide the QST optimization of the TS.
K = 1-9 Interpolation of initial guess of TS between R and P (TS = 0.1*J*R + 0.1*(10-J)*P, default J=5).
J = 1 LST constraint in internals.
J = 2 QST constraint in internals.
J = 3 LST constraint in distance matrix space.
J = 4 QST constraint in distance matrix space.
I = 0-9 Control parameters for climbing phase of QST (e.g. QSTRad = 0.01*I, default QSTrad = 0.05).

IOp(1/28)

-2 0.
-1 Normal (6 or 5 for linear molecules).
0 Default, same as -1.
N N.

IOp(1/29)

0 Defaults to 8 (by z-matrix).
1 By direct coordinate input (must set IOp(29) in L202).
2 Get z-matrix and variables from the checkpoint file.
3 Get Cartesian coordinates only from the checkpoint file.
4 By model builder, model A.
5 By model builder, model B.
6 Get z-matrix from the checkpoint file, but read new values for some variables from the input stream.
7 Get all input (title, charge and multiplicity, structure) from the checkpoint file.
8 Z-matrix.
10 Print details of the model-building process.
000 Default (same as 100).
100 Do not abort job if model builder generates a z-matrix with too many variables.
200 Abort job if model builder generates a z-matrix with too many variables.
1000 Read optimization flags in format 50L1 after the z-matrix.
2000 Set all optimization flags to optimize.
3000 Purge flags except the frozen variables.
4000 Rebuild the coordinate system.
5000 (2+3) Purge all flags but keep the coordinate definition.
6000 Generate new redundant coordinates, reading an input section selecting frozen and optimized atoms.
7000 Mark all internal coordinates as frozen before handling ModRed input
00000 Default, same as 10000.
10000 Mark z-matrix constants as frozen variables rather than wired-in constants.
20000 Do not retain symbolic constants.
100000 Generate a symbolic z-matrix using all Cartesians if none is present on the checkpoint file (a hack to make IRCs work with Cartesian input).
200000 Same as 1, but retain the redundant internal coordinate definitions.
400000 Do not read red. int coords when reading geom from chk.
1000000 Get input type or chk file name to read from input stream; title and charge/multiplicity for each structure read from input.
2000000 Read input type for each structure from input stream; title and charge/multiplicity are those of last chk file read.
9000000 Same as 0000000.
00000000 Default (read one set of charge/multiplicity
pairs unless both NFrag and ONIOM are set).
10000000 Read ONIOM charge/multiplicity pairs if reading
any. Fragment values will be defaulted from the supermolecule.
20000000 Read fragment charge/multiplicity pairs if reading any. ONIOM model system values will be defaulted from the real system.
30000000 Read two lines, with ONIOM followed by fragment values.
100000000 If reading from chk file, take coordinates in the standard orientation as the input orientation.
200000000 Default, use input orientation when reading from chk file.
1000000000 Quiet mode: turn off most print in l101.

IOp(1/30)

0 Yes.
1 No, print internal coordinate step but don’t set up for microiterations and don’t update the RWF.
2 Set up for step but don’t update coordinates; for QM/MM iterative frequencies.

IOp(1/32)

Title card punch control.

0 Don’t punch.
1 Punch.

IOp(1/33)


IOp(1/34)

0 Off.
1 On.

IOp(1/35)

0 Normal optimization.
1 First point of a restart. Get geometry, wavefunction, etc. from the checkpoint file.

IOp(1/36)

Checkpoint.

0 Normal optimization, IRC, numerical diff, or dynamics.
1 Restart, starting from info saved on the chk file.

IOp(1/38)

0 Continuation of run.
1 Initial entry.
N>1 In L103:  Initial entry of guided optimization using N levels.
N0 In L106:  differentiate Nth derivatives once. In L110 and L111: differentiate energy N times.
000 In L106: differentiate with respect to nuclear coordinates.
100 In L106: differentiate with respect to electric field.
200 In L106: differentiate with respect to field and nuclear.
1000 In L106: Save original forces and force constants.
00000 In L106: Assume all quantities available at the central point will also be computed at displaced points.
10000 In L106: No analytic nuclear coordinate derivatives will be done at displaced points, even though they were done at the central point.
000000 L106 control of number of diff. steps.
100000 Do 2-point differentiation (one step each way).
200000 Do 4-point differentiation (two steps each way).
400000 Do 2-point double differentiation (one step each way).
500000 Do 2-point double differentiation (one step each way).
600000 Do 4-point double differentiation (two steps each way).
0000000 Default (1).
1000000 Differentiate with respect to translation vectors for PBC for elasticity.
2000000 Do not differentiate with respect to translation vectors.
10000000 Initial energy block of a route for a job involving Link 129.

IOp(1/39)

0 Use internal default: 0.005 A in L109, 0.01 Angstrom in L110, 0.001 au in L111. In L106: numerical 1st: 0.001 A nucl, 0.001/3 au field, 0.010 A normal mode displ.; numerical 2nd, 2pt: 0.003 A nucl, 0.003/3 au field, 0.010 A normal mode displ.; numerical 2nd, 4pt: 0.010 A nucl, 0.010/3 au field, 0.010 A normal mode displ.
N Use step-size of 0.0001*N (angstroms in L106, L109, L110, electric field au in L111). In L106, the electric field step will be 3x smaller.
-1 Read step size (up to 2 for L106, 1 for others), free-format.
-N>1 Use step-size of 0.0001*N atomic units everywhere.
0 Default (0.1 Bohr, except 0.075 Bohr for EulerPC, or original value if restart. DVV default is 0.25 fs).
N<0 Supplied step size is in units of sqrt(amu)*Bohr.
N>0 Supplied step size is in units of Bohr.

IOp(1/40)

-1 Pick up analytic second derivatives every time.
0 Just update. The default, except for CalcAll.
N Recalculate the Hessian every N steps.
0 Start with 0.0.
1 Read from checkpoint file.
2 Read from input stream.
0 Default (10-8 Bohr).
N 10-N Bohr.

IOp(1/41)

Take previous geometry from checkpoint file:

N > 0 Nth point of geometry optimization (z-matrix only). Converted to -(N+1) if no z-matrix.
N < 0 Nth geometry on trajectory file.

IOp(1/42)

0 1.0D-10.
N 1.0D-N.

IOp(1/43)

0 Dipole.
1 Quadrupole.
2 Octapole.
3 Hexadecapole.
0 Default is 11.
1 Use internally stored Radii, centers will be on atoms.
2 Read-in centers and radii on cards.
10 Force Merz-Kollman radii (Default).
20 Force CHELP (Francl) recommended radii.
30 Force CHELPG (Breneman) recommended radii.
100 Read in replacement radii for selected atom types as pairs (IAn,Rad) or (Symbol,Rad), terminated by a blank line.
200 Read in replacement radii for selected atoms as pairs (I,Rad), terminated by a blank line.

Initial radius of spheres to be placed around attractors to “capture” the gradient trajectories. The final radius is then automatically optimized separately for each atom.

0 0.1
NM N.M=NM/10

IOp(1/44)

0 Optimization coordinates (Default 3 in L15 and L123, 2 in L125).
1 Cartesian.
2 Internal (NYI in L123).
3 Mass-weighted Cartesian (NYI in L125).
M0 Initial interpolation in L125 (default 2).
0 10.0 au.
NM N.M au = NM/10.
-1 Use system time initialize iseed (Note each run will give different results).
0 Use default seed value (ISeed = 398465).
N Set random number seed to N.

IOp(1/45)

00 Which IRC integrator to use. Default = 3, except 6 for ONIOM QuadMac/Micro or 1 for GradientOnly.
01 Euler.
02 LQA.
03 HPC.
04 GS2.
05 DVV.
06 Euler-based PC.
10 Coordinate driving schemes.
0xx Is the integration being done on an empirical surface? Default=2.
1xx Yes, this is an empirical surface. The energies and derivatives required for the IRC integration are NOT evaluated in this link. Instead it is assumed that an external program communicates the appropriate values with Link 402, etc. Also, the force constant matrix, when needed, is simply diagonalized, i.e. translation and rotation projections are NOT used. Also, all atomic masses are set to 1.
2xx No.
3xx Mass-weight but don’t remove translations and rotations.
0xxx Order of magnitude for the step size relative to the integer value given with the StepSize=N option on the route line — IOp(1/39). Default=2.
Nxxx Integration step size is taken as IOp(1/39)*10-N.
0xxxx Whether or not energies reported in the final summary table should be given relative to the TS energy. Default=1.
1xxxx Yes.
2xxxx No.
0xxxxx Whether or not statistics over coordinates should be converted to Angstoms/Degrees when reported in the summary table. Default=1.
1xxxxx Yes.
2xxxxx No.
0xxxxxx Should a URVA input file be written? Default=2.
1xxxxxx Yes.
2xxxxxx No.
0xxxxxxx Should IRC data besaved to the PES data structure file? Default=1.
1xxxxxxx Yes.
2xxxxxxx No.
0xxxxxxxx When second-order methods are employed, should the Newton-Raphson step test be carried out? Default=1.
1xxxxxxxx Yes.
2xxxxxxxx No.
0 default: ab initio calculation of energy and gradient at every step.
1 call external program to calculate energy and gradient.
10 Remove translational and rotational component of force every step

IOp(1/46)

Order of multipoles in numerical SCRF.

0 Dipole.
1 Quadrupole.
2 Octapole.
3 Hexadecapole.

IOp(1/47)

Number of internal coordinates, fragments, etc. to allow for.

0 Default: Max(50000,MCV/(100*NStruc))
N N.

IOp(1/48)

IRCMax control.

1 Do IRCMax.
20 Include zero-point energy.
0 Default 1000 (means 100 fs) for the centroid mode parameter (tau0) used in the PILE thermostat
N N/10 fs

IOp(1/49)

Options to IRC path relaxation (IJKL).

L 2/1 don’t/do optimize reactant structure. Default: 1.
K 2/1 don’t/do optimize product structure. Default: 1.
J 3/2/1 don’t/QST3/QST2 optimize TS structure (for QST input). Default: 1.
I 2/1 unimolecular/bimolecular reaction. Default: unimolecular.
0 default, don’t scale the mass for harmonic spring
N Scale the masses by 1/N for harmonic spring

IOp(1/50)

-1 Generate input for unchanged coordinates.
0 No.
1 Replace methyl and amino group coordinates with linear combinations, removing other coordinates involving these hydrogens.
2 Replace, but retain other angles involving the hydrogens.
3 Replace, but retain other angles and dihedrals involving the hydrogens.

IOp(1/51)

LMN Path second derivatives (default 213).
1 No 2nd derivatives, full path gradient only.
2 No 2nd derivatives, individual point gradients only.
3 Full path second derivatives.
4 Individual point second derivatives.
10 Identity matrix.
200 BFGS update.
K000 Path force definition (default 1)
1000 Orthogonal gradient
2000 Variational forces
J0000 Tangent/Curvature definition (default 3)
10000 Central difference
20000 Uphill difference
30000 Arc of Circle
40000 Cubic Spline
0 Conventional MD without density propagation
1 Time reversible extended Lagrangian TRXL-MD
2 ADMP
NN0 Initial state in non-adiabatic dynamics; e.g., 1=ground state, 2=first excited state, and so on.
NN000 Total number of electronic state in NAMD

IOp(1/52)

0/1 One layer, normal calculation.
2 Two layers.
3 Three layers.
00 Default (20).
10 Include electrostatics in model systems using MM charges (in case of three-layer ONIOM, this includes the charges in both the small model and the intermediate model system).
20 No electrostatics included in the model systems.
30 As 10, but exclude the MM charges in the calculations on the smallest model system in case of a three-layer calculation.
40 As 10, but exclude the MM charges in the calculations on the intermediate model system in case of a three-layer calculation.
100 Do full square for testing.
N000 Use atomic charge type N-1 during microiterations. The default is MK charges.
M0000 Type of link atoms for the MM calculation in QM/MM.
 
0 Default (2).
1 Conventional (Maseras) style.
2 ONIOM style.
L00000 Whether to read additional charges with electronic embedding.
 
0 Default (1).
1 No.
2 Yes.
K000000 Whether to create new entries in Common/Mol for the link atoms.
 
0 No.
1 Yes.

IOp(1/53)

0 Do nothing.
1 Set up point MM on RWF from initial data.
2 Set up point MM on RWF from initial data and restore point MM on checkpoint file if ONIOM data is present there.
3 Restore point M from data on the RWF.
4 Integrate energy.
5 Integrate energy and gradient.
6 Integrate energy, gradient, and Hessian.
7 Restore point MM from RWF but do not create a new model system.
8 Save point NN and restore point MM but do not do anything else.
NN0 Save necessary information (some RWF’s, energy, gradients, Hessian) of point NN of the ONIOM grid. NN = MaxLev2 + 1 (currently 17) to restore real system.
MM000 Next point to do is MM.
 
Calc Level
High 4—7—9*
|    |   |
Mid 2—5—8
|    |   |
Low 1—3—6
  S  M  L system size

IOp(1/54)

Whether to recover initial energy during IRCMax from checkpoint file.

0 No.
1 Yes.
1 normal-mode coodinate representation for beads (default)
2 staging coordinate representation for beads

IOp(1/55)

0 Old GDIIS uses gradients to find the next geometry.
1 Old GDIIS uses displacements to find the next geometry.
00 Default (20).
10 Use cartesian search on model surface to generate new step in cartesians from internals.
20    Use least-squares (RedCar) for conversion.

IOp(1/56)

Set of atom type names to parse.

0 Accept any.
1 Dreiding/UFF.
2 Amber.
3 Amber allowing any symbol, for use with parameters in input stream.
4 Amoeba; currently only the fluctuating charges are handled within Gaussian. Any symbols are accepted.

IOp(1/57)

Whether to produce connectivity.

0 Default (4 if reading geometry from checkpoint file and connectivity is there, otherwise 3).
1 No.
2 Yes, read from input stream.
3 Yes, generate connectivity.
4 Yes, read from checkpoint file.
5 Yes, read from RWF file.
10 Read modifications.
100 Connectivity input is in terms of z-matrix entries, including dummy atoms.

IOp(1/58)

1 Do IRC rather than IRCMax.
10 Store compound energy; default for IRCMax.
20 Zero-point energies are available during IRCMax.

IOp(1/59)

0 Default (1).
1 New versions (RedCar/RedQ2X); fall back to ORedCr/RedQX1 if RedCar fails.
2 Old version (ORedCr/RedQX).
3 Old version (ORedCr/RedQX1).
4 New version (ORedCr/RedQ2X) but fall back to ORedCr/RedQX if RedCar fails.
5 ORedCr/RedQX/RedQX2 (linear step only).
6 Search in cartesian coordinates, falling back to RedCar if necessary.
MMMM0 IAprBG in Red2BG.
10 Re-use eigenvectors of G only if exact.
20 Re-use eigenvectors of G if they are linearly independent.
30 Test old eigenvectors of G but don’t re-use them.
40 Don’t look at old eigenvectors.
50 Re-use eigenvectors of G if the RMS of the elements of the new G in the old null space is less than the threshold.
NN00 RMS < 10-N, default 4.
M0000 Default (1).
10000 Form G-inverse from the B eigen-values/vectors.
20000 Form G-inverse directly from G.
30000 Do G- via diagonalization of G (NYI).
40000 Do G- via SVD on B, returning only the eigenvectors with nontrivial eigenvalues.

IOp(1/60)

Interpret extra integer and fp values in z-matrix as scan information.

0 Default (No).
1 Yes.
2 No.

IOp(1/61)

How ONIOM should leave the RWF at the end of each geometry.

0 Default (1).
1 Normal: leave the RWF set up for the low-level calculation on the real system.
2 MOMM: leave the RWF set up for the real system, but with NBasis and NBsUse for the high-level calculation on the model system. Useful for treating the full system as having electrons only on the QM atoms. This is really a hack for two layer QM:MM ONIOM ADMP and should probably be generalized to behave like an ONIOM-PCM-A case.
3 Lowest level is MO, but normal setup at end.
00 Default (10, but 20 if doing EE microiterations).
10 Leave the charges file (605) from the best calculation that produced one.
20 Leave 605 in its normal state (present if from real, low-level).
000 Default (200).
100 Do low-level calculations on full model system, ignoring fragments, even if using fragments on high level.
200 Split model systems for all models.

IOp(1/62)

Counterpoise control.

NN NN fragments.
1NN Force use of new ghost atoms (default).
2NN Force use of old ghost atoms.
1xxx Counterpoise (default).
2xxx Fragment guess.

IOp(1/63)

Step in counterpoise calculation.

LMM L: order of derivatives: 1 = Energy, 2 = Gradient,…
  MM: 0 = Supermolecule, 1-NFrag = Fragments with ghost atoms,
  NFrag+1-2*NFrag = lone fragments.

IOp(1/64)

Molecular mechanics force field selection.

-1 Treat as MM for microiterations but don’t set up parameters.
0 None.
1 Dreiding.
2 UFF.
3 AMBER.
8 Amoeba. Currently does only the electrostatics and doesn’t warn about missing other parameters.
9 Accept any symbols and don’t worry about missing parameters.
000 Use only hard-wired.
100 Use soft and hard-wired, hard-wired has priority.
200 Use soft and hard-wired, soft has priority.
300 Use only soft. Lowest 2 digits then have no meaning.
0000 Do not read modifications to parameter set.
1000 Read modifications to parameter set.
00000 With soft parameters, abort when different parameters match to the same degree.
10000 Use the first when there are equivalent matches.
20000 Use the last when there are equivalent matches.
000000 Default (100000)
100000 Default: obviously wrong valences in the connectivity are errors.
200000 All suspicious valences are errors.
300000 All suspicious valences are warnings.
0000000 Default (1000000)
1000000 If non-H atoms have charges but no vdw repulsion, it is an error.
2000000 If any atoms have charges but no vdw repulsion, it is an error.
3000000 If non-H atoms have charges but no vdw repulsion, it is a warning.
4000000 If any atoms have charges but no vdw repulsion, it is a warning.

If IOp(67) = 3, then the default is to apply soft parameters with higher priority.


IOp(1/65)

Control of which terms are included in MM, corresponding to the ‘classes’ in FncInf.

0 Do all (default).
1 Non-bonded.
10 Stretching.
100 Bending.
1000 Torsion.
10000 Out-of-plane.
100000 Stretch-bend.
1000000000 Do not abort on missing parameters. The default for ONIOM=HighOnly.
2000000000 Terminate on missing parameters. The default except for HighOnly.

IOp(1/66)

Whether to generate QEQ charges, over-write the values in AtChMM, or to use the values already there.

0 Default (2, 1 ⇒ 221).
1 Do QEq here in GenChg.
2 Don’t do QEq.
3 Generate charges here using QEqN.
00 Default (20).
10 Do for atoms which were not explicitly typed.
20 Do for all atoms regardless of typing.
000 Default (200).
100 Do for atoms which have charge specified or defaulted to 0.
200 Do for all atoms regardless of initial charge.
MMMMM000 IType passed to QEq.

IOp(1/67)

Source of MM parameters.

0 Default: 2 if reading geometry from checkpoint file, else 1.
1 Generate here, reading from input if requested by IOp(64).
2 Copy from checkpoint file.
3 Pick up non-standard parameters from checkpoint file.

IOp(1/68)


IOp(1/70)

0 Default (same as 3).
1 Orthant sampling.
2 Classical microcanonical normal mode sampling.
3 Fixed normal mode energy.
4 Local mode sampling (thermal sampling based on RTemp).
Currently 0, 2, 3 and 4 are working.
10 Read in Hessian from checkpoint for initial sampling.

L124: SCRF flag.

IJKLLMM See comments in overlay 3.
00000000 Default (same as 2).
10000000 Do the 1st iteration in gas-phase.
20000000 Do the 1st iteration in solution.

IOp(1/71)

0 Default (every cycle if IOp(10)=4).
N Every Nth geometry, starting with the initial one.
0 No.
1 Yes.
-1 Gradient only.
-2 Gradient+Hessian, but never calculate full H (only updates).
0 Full Hessian at every step.
NN Try to do NN updates between full Hessians.
000 Default updating (same as 300).
100 SR1 Hessian updating algorithm.
200 PSB Hessian updating algorithm.
300 Bofill’s Hessian updating algorithm.
400 Sqrt(Bofill) Hessian updating algorithm.
500 No update.
0000 Default (same as 1000).
1000 Reintegrated updated steps.
2000 Suppress reintegration.
-1 Gradient only.
0 Either only update or CalcAll as determined by IOp(10).
N Recalculate analytic Hessian every Nth calculation.

IOp(1/72)

Half*Gamma*Tr[(P*P-P)2] + Lambda*[Tr(P)-Ne] + Eta*Tr(P*P-P)
0 Default same as 7 if no mass-weighting (IOp(76) < 0). Same as 10 if mass-weighting (IOp(76) > 0).
1 Use Lambda and Eta only. (Gamma=0).
2 Use Lambda, Eta, Gamma. Gamma = .2.
3 Use Lambda, Eta, Gamma. Gamma = 1. Constraints for scalar mass case.
4 Use exact constraint Sum(ij)[Vij*(P2-P)ij].
5-7 Iterative Scheme same as 4. Different initial guesses. 7 is default for scalar mass case. Constraints for tensorial mass.
8-11 Mass-weighting constraints. Documentation may be found in DVelV1. 10 is default.

IOp(1/73)

0 Default (.1 Hartree).
N>0 N*micro-Hartree.
N<0 0.0 Hartree

IOp(1/74)

Charge scaling for charge embedding in ONIOM.

IJKLMN The 6th through 1st nearest neighbors of the current layer are scaled by I*0.2, J*0.2, etc. 0 → 5 → IAtTyp=6 (no scaling); all layers are scaled by at least as much as ones farther out. The default is 500.
M Factor for charges one bond away from link atom.
L0 Factor for charges two bonds away from link atom.
K00 Factor for charges three bonds away from link atom.
J000 Factor for charges four bonds away from link atom.
I0000 Factor for charges five bonds away from link atom.
The actual factors used for each value of IAtTyp are: 1: 0.0; 2: 0.2; 3: 0.4; 4: 0.6; 5: 0.8; 6: 1.0.

IOp(1/75)

0 Standard ADMP.
1 Read converged density at every step.
2 Fix the nuclear coordinates.
3 Test time reversibility (MaxStp must be even).
00 Default (20).
10 Read stopping parameters from input.
20 Do not read stopping parameters.
NNx01 PIMD
NNx02 RPMD (default)
NNx03 PIMD + Harmonic Potential for adiabatic switching
NNx04 RPMD + Harmonic Potential for adiabatic switching
NN000 Dynamics on a single electronic state surface
NN010 Ehrenfest solving TDSE for each bead
NN020 Ehrenfest solving TDSE for centroid
NN030 Surface hopping solving TDSE for each bead
NN040 Surface hopping solving TDSE for centroid
NN050 CSDM solving TDSE for each bead
NN060 CSDM solving TDSE for centroid
NN000 number of beads — NN

IOp(1/76)

Fictitious electron mass (EMass). Format of input: +/- XXXXZYYYY.

YYYY Default (1000)
  IOp(1/76) > 0  YYYY*.0001 amu. MW core functions more than valence functions.
  IOp(1/76) < 0  YYYY*.0001 amu. Use uniform scaling for all basis functions.
  (Note YYYY > 9999 makes no sense).
Z Mass-weighting option. If IOp(76) < 0, Z is meaningless.
Z=1 Default fixed masses.
Z=3 Atomic core AO weighting.
Z=4 Atomic core AO energy weighting.
Z=5 Atomic core AO radius weighting.
Z=6 Hessian-based update schemes.
XXXX If PBC: Mass of Box Coordinates (BoxMas) = XXXX*.0001 AMU BoxMas=0
  Box coordinates not propagated (default).

IOp(1/77)

Initial Kinetic energy of the density matrix (EStrtP) (For UHF, Alpha and Beta each get half this energy) and Option Number to compute initial kinetic energy. Format of Input: XXYYYY (six digits).

IWType = XX
N = YYYY

(For UHF, Alpha and Beta each get half this energy).

0 Default (0.0 Hartree).
N>0 N*micro-Hartree IWType is used to figure out how the initial velocity is computed (in gnvelp).
If XXYYYY < 0: Initial velocity = 0.0 Hartree (i.e., currently same as N=0 above).

IOp(1/78)

-N Sparse here with cutoff 10-N, full elsewhere.
0 Use full matrices or sparse based on standard settings.
1 Use sparse fixed form.

IOp(1/79)

0 Default, do not analyze pure rotation and vibration for polyatomic molecules.
1 Do pure rotational and harmonic normal mode analysis for polyatomic molecule; EBK theory for diatomic vibrational analysis (require equilibrium information for each of the polyatomic molecules from saved checkpoint files and Morse parameters for diatomic molecule).
2 Do pure rotational and harmonic normal mode analysis for polyatomic molecule; local harmonic vibrational analysis for diatomic molecule (require equilibrium information for each of the fragments from saved checkpoint files).
3 Do pure rotational analysis and select the best normal mode analysis methods (harmonic and anharmonic) for polyatomic molecule; local harmonic vibrational analysis for diatomic molecule (require equilibrium information for each of the fragments from saved checkpoint files).
00 Default, use default stopping criteria.
10 Use user specified stopping criteria.
0 Do not check the stop criteria by GICs. Trajectory stops at MaxSteps.
N Check the GICs stop criteria every N steps.

IOp(1/80)

0 No Thermostat.
11XXXXX Velocity scaling, but only for the first XXXXX simulation steps. (This option is useful, if thermostating is only required during equilibration.)
1000000 Velocity scaling, all the way through the simulation.

IOp(1/81)

Nuclear KE thermostat in ADMP — temperature is checked and scaled every IOp(81) steps.

0 turn off thermostat
1 thermostat to all modes
2 thermostat to all modes except centroid mode
1x PILE thermostat; See Ceriotti, et al. JCP 133, 124104 (2010).
2x PILE-M (BAOAB) scheme; See Liu, et.al. JCP 145, 024103 (2016). Default thermostat.
3x Andersen (NIY)
4x Nose-Hoover chain
5x Brownian Chain MD (randomize momenta)

IOp(1/82)


IOp(1/83)

Whether to read in frequencies for electric and magnetic perturbations.

0 Default (No).
1 Yes unless geom=allcheck.
2 No.
3 Yes, even if geom=allcheck.
00 Default (10).
10 Ensure that the static case is done, by putting a zero frequency at the beginning.
20 Do not put a zero frequency at the beginning.
000 Default (100).
100 Sort the frequencies into increasing order.
200 Do not sort the frequencies (for debugging).

IOp(1/84)

Differentiation of frequency-dependent properties.

0 No.
N Mask for which properties on file 721 will be differentiated.

IOp(1/85)

Band gap calculation in PBC ADMP.

0 Default (No).
1 Diagonalize Fock matrix to get band gap, evolution, etc.
2 No.

IOp(1/86)

Printing for NMR for ONIOM.

0 Default (1).
1 Print tensors and eigenvalues.
2 Print eigenvectors as well.

IOp(1/87)

ONIOM integration of density.

0 Do not integrate.
1 Integrate current densities.
2 Integrate densities specified by following digits:
K0 Density to use from gridpoint 1
L00 Density to use from gridpoint 2
M000 etc.
Values for K, L, M, etc.:
  0: SCF
  1: MP first order
  2: MP2
  3: MP3
  4: MP4
  5: CI one-particle
  6: CI
  7: QCI/CC
  8: Correct to second order

IOp(1/88)

Whether to read in atomic masses (isotopes) and new assignment of atoms to fragments.

0 Default (1 if geometry read from input, 4 if geometry read from checkpoint)
1 Use most abundant isotopes.
2 Read isotopes from input. The temperature and pressure are read first, for backwards compatibility.
3 Read isotopes from RWF.
4 Read isotopes from checkpoint.
5 (Generated internally) Isotopes were read from chk file during Guess=Input.
0x Do not read MK radii.
1x Read MK radii for elements.
2x Read MK radii for atoms.
3x Read MK radii from rwf.
4x Read MK radii from chk.
5x (Generated internally) radii were read from chk file during guess=input.
000 Default (do not read new fragment assignments).
100 Read an input section with atoms in each fragment, separated by / between fragments. Atoms not listed are assigned to an additional fragment.
200 If fragments were not specified, do not default them based on the connectivity.

IOp(1/89)

Maximum allowed deviation from average nuclear KE during ADMP, in Kelvin.


IOp(1/90)

To read in the velocity in Cartesian coordinates.


IOp(1/91)

Nuclear Kinetic Energy Thermostat Option. Average energy (in micro-Hartree) to be maintained during simulation, as required by IOp(80).


IOp(1/92)

Thermostat Option. Maximum allowed deviation from average nuclear KE specified in IOp(81). Also in micro-Hartree.


IOp(1/93)

QM/MM TS vector guess.

000 Default (312)
1 Retrieve from checkpoint file if available, otherwise diagonalize QM Hessian or read from input.
2 Do not try to retrieve from checkpoint file.
10 Diagonalize QM contribution to Hessian.
20 Read from input.
N00 How to deal with ‘suspicious RFO solutions’ (default is 1).
  1. Just take the step.
  2. Check if there is an eigenvector with wrong curvature. If there is, flip its eigenvalue.
  3. Check if there is an eigenvector with wrong curvature. If there is, take a small step into this direction, followed by a linear search. This should step out (or stay in) the wrong region, and fix the eigenvalue.

IOp(1/94)

Davidson control for quadratic micro-iterations.

OP Number of initial guess vectors (4).
MN00 Iteration to scale down number of vectors (5).
KL0000 Factor to scale down with; 1 for no scaling (2).
J000000 Whether to do geometry steps when the CG is done (2).
 
1 Make the CG steps.
2 No displacements.
3 Only do displacements at first guess.
I0000000 Whether to re-use previous RFO solution or to regenerate guess (1).
 
1 After first step, use previous solution as guess.
2 Regenerate guess each time.
3 Use previous lowest root, and regenerate remainder.
H00000000 Whether (1, default) or not (2) to add 0,…,0,1 guess vector.

IOp(1/95)

RFO/Davidson control for quadratic micro-iterations.

MM Convergence (7).
LLL00 <0: Regular Davidson.
0: Only check convergence on first vector, and iterate the lowest root only. Use all the intermediate vectors.
>0: Only check convergence on first vector, and iterate the new vectors LLL times with the explicit last row/column. This is specifically appropriate for RFO. The last row/column of the Hessian comes after the diagonal elements.

IOp(1/96)

Options for generating initial guess vectors for RFO/Davidson diagonalization in coupled QM/MM macro steps. Note that other RFO/Davidson diagonalization controls for coupled QM/MM macro steps are available in IOp(97). Format of input: GHIJKLLMM.

MM Number of initial guess vectors to get from CG steps. The default is 0.
LL Number of initial guess vectors from the diagonal of the QM block (4). The default is 4.
K Add 0,…,0,1 guess vector?
0 Default: K = 1;
1 Yes
2 No
J Add the gradient vector to the guesses?
 
0 Default: J = 1
1 Yes
2 No
I Pre-diagonalize a Hessian/RFO matrix without non-bonding contributions? Note that this control is only valid for IOp(98) > 3; otherwise, I is ignored.
 
0 Default: I = 1
1 Yes
2 No
H Scale factor for the size of the Davidson sub-space in early iterations.
 
0 Default: H = 4
1 Same as no scaling.
H Use a sub-space in early iterations that is H times the number of requested vectors.
G Number of vectors to solve using Davidson diagonization.
 
0 Default: G = 1
G Solve for G vectors.

IOp(1/97)

RFO/Davidson control for coupled QM/MM macro step. Note that other RFO/Davidson diagonalization conrols for coupled QM/MM macro steps are available in IOp(96). Format of input: GHIJKLMM.

MM Convergence in Davidson iterations. Convergence is set to 10-MM. The default value is MM=5.
L What is being diagonalized? This option is set explicitly in subroutines before calling the Davidson diagonalization code. Therefore, the value set in this IOp is ignored and serves only as a place holder.
0 the Hessian
1 the augmented-Hessian/RFO matrix
K Check convergence on which roots?
0 Default: For L=0, K=2; For L=1, K=1
1 Check convergence on lowest root only.
2 Check convergence on all roots.
J Appears to be unused.
I Number of Davidson iterations to store.
0 Default: Keep all iterations.
1 Keep only the last iteration.
H Number of new vectors to create in each Davidson iteration.
0 Default: For L=0, H=1; For L=1, H=2.
1 Iterate all roots/vectors.
2 Iterate lowest root/vector only up to the maximum number of iterations that are default in the Davidson code (ignores J above) and keeping vectors from all iteratations (ignores I above).
3 Iterate lowest root/vector only. Note that this option is essentially the same as H=2, though J and I option settings are honored.
G Initial approximation to use for Davidson diagonization.
0 Default: G=2.
1 Use a diagonal Hessian approximation together with the gradient vector. This is best used in RFO applications
2 Use the inverted Hessian for the QM block
3 Use a diagonal Hessian approximation.

IOp(1/98)

Control of quadratic micro-iterations and coupled QM/MM quadratic macro step.

<0 Do not use dynamic convergence criteria for the micro-iterations.
0 Default (11).
1 Regular non-coupled macro step.
2 Coupled macro step, full diagonalization.
3 Coupled macro step, direct /w full Hessian in core.
4 Coupled macro step, direct /w MM Hessian in core.
5 Coupled macro step, fully direct.
6 Go through the QuadMac machinery, but use the fully integrated ONIOM Hessian to calculate the Hessian-vector products. Switch to regular micro-iterations at points without analytic second derivatives.
7 Fully quadratic at 2nd derivative points (1st in CalcFC, all in CalcAll), QuadMac with integrated Hessian at non-2nd derivative points.
10 Regular micro-iterations.
20 Quadratic micro-iterations, full diagonalization.
30 Quadratic micro-iterations, direct with prepared Hessian in core.
40 Quadratic micro-iterations, direct with raw MM Hessian in core.
50 Quadratic micro-iterations, fully direct.
60 No micro-iterations.

IOp(1/99)

Accuracy used for the non-bonded interactions in the Hessian-vector product calculations in the fully direct algorithms. Setting this IOp does not affect the MM energy and gradient calculations; only the direct evaluation in the QuadMac optimization step. When IOp(99) < 0, the full accuracy is used.

MM Maximum multipole level (8)
LLL00 Box size in FMM (12)
KKK00000 Cutoff in van der Waals (30)

IOp(1/101-104)


IOp(1/105)

Reaction direction.

Damped-Velocity Verlet (DVV) options for Dynamic Reaction Path following.

00 Default (Same as 10).
10 Forward direction.
20 Reverse direction
0 Default (Same as 2).
1 Use DVV.
2 Do not use DVV.
00 Default (Same as 10).
10 Follow the rxn path in the forward direction
20 Follow the rxn path in the reverse direction.
000 Default (Same as 200).
100 Time step correction not used.
200 Time step correction used but not to recalculate current DVV step.
300 Time step correction used and current DVV step recalculated.
0000 Default (Same as 1000).
1000 Use DVV stopping criteria.
2000 Do NOT use DVV stopping criteria

IOp(1/106)

Damping constant for DVV Dynamic Reaction Path following (v0).

0 Default v0 = 0.04 (N=400).
N v0 is set to N*0.0001.

IOp(1/107)

Error tolerance for DVV time step correction (Error).

0 Default Error = 0.003 (N=30).
N Error = N*0.0001.

IOp(1/108)

Gradient magnitude for DVV stopping criteria (Crit1).

0 Default (N = 15).
<0 Turn off this test.
N N*0.0001

IOp(1/109)

Force-velocity angle for DVV stopping criteria (Crit2).

0 Default (90 Degrees).
<0 Turn off this test.
N Use N Degrees.

IOp(1/110)

Scaling of rigid fragment steps during microiterations.

0 Do not scale.
1 Scale with 1/NRA (NRA = number of atoms in fragment).
2 Scale with 1/Sqrt(NRA).
-n Scale with 1/n.

IOp(1/111)

-N Scale up to RMS step of N/1000 if DXRMS is less.
-1 Effectively disables the scaling.
0 Default (-5 for special GICs, 50 for other cases).
N Scale up or down to maximum change in a variable of N/1000.

IOp(1/112)

0 Default (standard temperature, unless read in).
N N/1000 degrees.
1 Default.
-N<1 N/1000000 degrees.
-N N/1000000 degrees.

IOp(1/113)

Pressure for thermochemistry.

0 Default (1 atmosphere, unless read in).
N N/1000 atmospheres.
-1 Default.
-N<1 N/1000000 atmospheres.

IOp(1/114)

Scale factor for harmonic frequencies for use in thermochemistry and harmonic vibration-rotation analysis.

0 Default (1 unless specified by IOp in overlay 7 or read in).
-1 Force to 0 (default).
N N/1000000.

IOp(1/115)

Compression for MOMM quadratic steps.

4 Second derivatives generated over active atoms, with real system terms done iteratively during micro-iterations.
N¹4 Full second derivative matrices are used.

IOp(1/116)

Options for ONIOM Conical intersections: which calculations have adiabatic couplings done.

0 Default (111 all component calculations).

IOp(1/117)

0 No MMVB
1 Do MMVB calculation.
11 Do MMVB dynamics allowing for surface hop.
000 Activate Bridging Corrections to Kij and Qij (Default)
100 Does Not Activate the Bridging Corrections
200 Activates Marco’s Bridging Corrections
300 Activate GAUCA-MMVB Bridging Corrections (for debugging only)
400 Activate GAUCA-MMVB Marco’s Bridging Corrections (for debugging only)
0000 No Conical Intersection Search (Default)
1000 Search For Conical Intersection For (LRoot,LRoot-1)
00000 Do not Delete any Coulombic Qij.
10000 Specify Qij to delete.
000000 E(MMVB)=E(MM)+E(VB), G(MMVB)=G(MM)+G(VB) (Default)
100000 E(MMVB)=E(VB), G(MMVB)=G(VB)
200000 Option 2 in the original GAUCA-MMVB code (NYI)
0000000 Solve VB problem numerically with Lanczos
1000000 Solve VB problem analytically
00000000 Hartree-Waller functions for singlets or triplets
10000000 Slater determinant
000000000 Use correct conversion factors
100000000 Use GAUCA-MMVB conversion factors (for debugging only)

IOp(1/118)

Dump structures for each ONIOM or counterpoise step formatted as input.

0 Default (No).
1 Yes.
2 Yes, just dump input without doing any calculations.

IOp(1/119)

Control Initial Lanczos Vector (ILzVec).

-1 Read guess by card in input file.
-2 Use the largest elements of H as a guess.
-3 Use the five largest contributions of H as a guess.
0x For Opt, IRC, dynamics read guess from previous cycle.
1x For Opt, IRC, dynamics generate a fresh guess for each cycle

IOp(1/120)

Flags for QM:QM embedding. NOTE: The standard embedding flags must also be set in the same way as necessary for QM:MM embedding calculations.

0 Default – Same as 1.
1 Use Mulliken charges.
-1 Use the nuclear charge stored in array AtmChg.
-2 Set the charges to zero.
00 Default (Same as 20).
10 Just use the charges that already reside in AtChMM.
20 Update AtChMM using current atomic charges on the RWF.

This option is only employed immediately following low-level real-system sub-calculations.


IOp(1/121)

0 Default, none.
1 Differentiate AO density and Fock matrices.
2 NYI.

IOp(1/122)

Read secondary structure information.

0 Default (4 or 3 if reading geometry from checkpoint or RWF file, otherwise 2).
1 No.
2 Yes, read from input stream if any residue information was provided on the atom definition lines.
3 Yes, read from RWF.
4 Yes, read from checkpoint.

IOp(1/123)

Version of /Mol/ to save on disk.

0 Default (current, version 2).
1 Version 1 (flag -12345).
2 Version 2 (flag -12346).
N<0 Flag value N.

IOp(1/124)

Flavor of ONIOM-PCM to use.

1 “A,” reaction field from the ONIOM integrated density;
2 “B,” reaction field from the real system low level;
3 “C,” reaction field in the real system low level only;
4 “X,” reaction field in all subcalculations using the real system cavity.
0x Default (same as 1 unless a semiempirical method is involved);
1x Integrate the density for ONIOM-PCM-A;
2x Integrate the potential for ONIOM-PCM-A;
1xx Flag to indicate ONIOM-PCM-X as first iteration of ONIOM-PCM-A.

IOp(1/125)

Solvent charge distribution to add to Hamiltonian.

0 None.
1 Read charges and DBFs from input stream in input orientation.
2 Read from RWF.
3 Read from checkpoint file.
4 Same as 1.
5 Read charges and DBFs from input stream in standard orientation.
10 Force units of Angstroms for coordinates.
20 Force units of Bohr for coordinates.
100 Flag for external charges.
1000 Flag for SCS charges.
00000 Default (20000).
10000 Read DBF as well as charge information if reading from input
20000 Read only charge information if reading from input.

IOp(1/126)

Whether to read an input section with atom opt/freeze information.

0 Default (2).
1 Yes.
2 No.

IOp(1/127)

Use of MM coordinates and forces in GEDIIS:

0 Default (-3 for ME, -3 for EE).
-3 Don’t pass MM info.
-2 Zero MM forces and MM part of step, equivalent to not passing MM info.
-1 Zero MM forces but interpolate step in MM coords.
N Use MM forces scaled by 1/N.

IOp(1/128)

Initial micro-iterations in L120 before first QM step, and micro-iterations in L120 during numerical differentiation in L103.

0 Default (No).
1 Yes.
2 No.

IOp(1/129)

0 Default (none).
1 Read user-defined stats from the input file.
0x Default (do not report all Cartesian coordinates).
1x Report all Cartesian coordinates.
0xx Unused.
0xxx Default (do not report bond coordinates).
1xxx If redundant internals are on the RWF, then report values for bond coordinates along the IRC.
2xxx If redundant internals are on the RWF, then report all coordinate values and store in the OT file.
3xxx If redundant internals are on the RWF, then report all coordinate values and forces and store in the OT file.
0xxxx Default (do not report angle coordinates).
1xxxx If redundant internals are on the RWF, then report values for angle coordinates along the IRC.
0xxxxx Default (do not report dihedral coordinates).
1xxxxx If redundant internals are on the RWF, then report values for dihedral coordinates along the IRC.

IOp(1/130)

Eigenvector number to be followed during coordinate driving jobs (IOp(1/19 = 10)).

0 Default (1).
N Follow input structure Hessian eigenvector number N.

IOp(1/131)

Options for corrector integration in predictor-corrector IRC calulcations (Link 123).

00 Should the corrector integration scheme be run in an (macro-cycle) iterative fashion? Default = 2.
-01 After each corrector integration, evaluate the actual energy and derivatives, but do not actually use
these. The final IRC will be the same as 1.
01 Never check convergence of the corrector integration. Always do one corrector integration for each predictor integration.
02 Always check for convergence of the corrector integration end point. Convergence is acheived when the change in corrector integration end point geometry is less than the convergence criteria indicated by IOp(7).
03 Same as 2, but never accept convergence after the first corrector integration at a point.
10 This flag iteratively refines the DWI fitted surface if multiple corrector integration macro-cycles are taken by adding the largest standard deviation point from the previous BS cycle.
-11 This flag forces a PES evaluation step after each corrector integration. This is similar option -1, except that the actual energy and derivatives are used for the next predictor step rather than the values on the DWI fitted surface at the corrector end-point.
0xx Should DWI surfaces employ numerical thrid-order terms in Taylor series? Default = 1.
1xx Use DWI surface with Taylor series expansions truncated at second-order.
2xx Use DWI surface with Taylor series expansions truncated at third-order using numerical third-derivatives.
Nxxx What power should be used for DWI weights that include delta-x raised to an even power. The value of this option setsthat power to 2*N. Default = N = 1.
0xxxx How should the first step off of the transition structure point be handled in corrector integration cycles? Note, in all cases, the transition vector is used to define the tangent at the transition structure. Default = 2.
1xxxx Run the requested number of Euler steps in the standard way. Only the first Euler step taken uses the transition vector.
2xxxx Take a large step off of the transition structure point along the transition vector. This step is taken to be half of the total requested step size given by TotStp.
3xxxx This the same as option 2 in concept. The only difference is that the first step off of the transition structure is taken as one-third the total requested step size given by TotStp.
4xxxx This the same as option 2 in concept. The only difference is that the first step off of the transition structure is taken as one-fourth the total requested step size given by TotStp.
0xxxxx Should update vectors be used in DWI fits if possible? Default = 1.
1xxxxx Yes, when possible.
2xxxxx Never.

IOp(1/132)

Whether to check for divalent link atoms in ONIOM input:

0 Default (yes).
1 Yes.
2 No.

IOp(1/133)

Suppress integration/restore of quantities for Polar=Raman and Polar=ROA ONIOM jobs:

0 Default (1).
1 Do not restore or integrate forces, force constants, static electric or magnetic field derivatives.
2 Restore all files.

IOp(1/135)

MM non-bonded switching function.


IOp(1/136)

MM van der Waals outer cutoff in Angstroms.


IOp(1/137)

MM Coulomb outer cutoff in Angstroms.


IOp(1/138)

MM soft cutoff range (applied to both vdW and Coulomb, in Angstroms.


IOp(1/139)

Number of microiterations allowed (MMMMMNNNNN).

NNNNN NNNNN MM microiterations, default based on NAtoms but at least 5000.
MMMMM MMMMM model-surface microiterations.

IOp(1/140)

Whether to restore the real system from chk file:

0 Default (yes if ONIOM).
1 Yes.
2 No.

IOp(1/141)

Control of error choice during GEDIIS:

0 Default (1).
1 Use RFO steps as error vectors, using the NR step at a point if the RFO fails or gives a Hessian eigenvector.
2 If RFO fails for any point, use the gradient for all points.
3 Always use the gradients as the errors.
4 Use RFO steps as error vectors unless any RFO fails and unless Hessian is marked as untrustworthy; then use gradients instead.
5 Drop back to RFO (no DIIS) if Hessian is untrustworthy. NR steps are used if RFO fails during DIIS.

IOp(1/142)

Whether to copy MM charges to link atoms:

0 Default (3 if QEq is done; otherwise 1).
1 Copy if link atom charge is zero.
2 Do not copy.
3 Always copy.

IOp(1/143)

Hessian during IRC restarts.

0 No change in when Hessian is done.
1 Do Hessian at first new point in each direction.

IOp(1/144)

Whether to analyze residue geometry.

0 Default (Yes, if secondary structure present and N Atoms ≤ 10000).
1 Yes.
2 No.

IOp(1/145)

Controls for the new internal coordinate data structure.

0 Should the new internal coordinate data structure be set-up for use? (Default based on 1000000’s digit but GICs are turned off for Opt=Big).
1 No.
2 Yes. The coordinates are either generated by default (e.g., Option 9×2) or obtained from the user-provided input (e.g., Option 6×2). Alternatively, they can be taken from a chk file if they exist there and if geom=check without any GIC keyword (i.e., IOp(1/145=0) is used.
3 Yes, but do two calls to CrdDef when building the coordinate definitions. The first call adds the coordinates in the same way that Option 2 does. The second call adds coordinates from a list of user-provided input coordinates in the same way as Option 6×2 does. In other words, there will be two sets of coordinates to be merged. The first set is generated by default (e.g., in the case of Option 9×3 without geom=check) or it comes from a chk file (Option 9×3 with geom=check). The second set is provided by the user as a separate input section, and it contains some additional coordinates or modifications to the first set. A blank line can be used instead of the second set’s input section. It is also possible to make the user-provided input’s reading to be the first step and the construction of complementary coordinates by CrdCon to be the second step. The latter is Option 6×3.
0x Which coordinate derivative terms should be included in the data structure? (Default = 3x if Hessian is requested, 2x otherwise).
1x Include only values in the definitions list.
2x Include only values and their first-derivatives for B-matrix formation.
3x Include values and first- and second-derivatives for B-matrix and B-matrix derivatives.
4x Do 3 but turn off smart differentiation (UsSmDq) in CrdDq1 (for debugging).
0xx How should the new code define the coordinate set used when building the data structure? (Default=9xx
1xx Use the old coordinate generation code to build IZRed, then have CrdDef build the data structure using IZRed for the coordinates and build derivatives wrt Cartesian coordinates.
2xx Read the coordinate definitions from the input file using “Format 2” defined in routine CrDf01, and then automatically differentiate the active coordinate derivatives as needed.
3xx Read the coordinate definitions from the input file using “Format 2” defined in routine CrDf01, and then read in the derivative definitions (one set for IOp(145)=x1x; two sets for IOp(145)=x2x) from the input file using “Format 9” defined in Routine CrDf01.
4xx Read the coordinate definitions from the input file using “Format 2” defined in routine CrDf01, and then read in the first-derivative definitions using “Format 9” as defined in Routine CrDf01. If second-derivatives are requested (IOp(145)=x2x) then read in the second-derivative definitions using “Format 8” as defined in Routine CrDf01.
5xx Read the coordinate definitions from the input file using “Format 2” defined in routine CrDf01, and then read in the first-derivative definitions using “Format 8” as defined in Routine CrDf01. If second-derivatives are requested (IOp(145)=x2x) then also read in the second-derivative definitions using “Format 8” as defined in Routine CrDf01.
6xx Read the coordinate definitions from the input file using the symbolic form, (See Routine CrInp1), and then automatically differentiate the active coordinate derivatives as needed.
7xx Define (the full set of) distance matrix coordinates. This option can be combined with 2xxx to use inverse distance matrix coordinates.
8xx Read the coordinate definitions from the input file using the OLD symbolic form (See Routine CrDfSy), and then automatically differentiate the active coordinate derivatives as needed.
9xx Use the new coordinate generation code to create an intermediate RP structure using CrdCon, then have CrdDef build the data structure using the intermediate RP data and build derivatives wrt Cartesian coordinates. Subroutine CrdCon will use the current connectivity matrix by default, except for a case when IOp(1/156)=5 is requested. If so, the GICs will be obtained by CrDf32 called from CrdDef using the input Z-Matrix.
0xxx When building the internal coordinate definitions, should any systematic modifications be done? (Default = 9xx).
1xxx No. Simply define the coordinates to be the same as they would have been using the old coordinate code. 2xxx … Invert all bond stretch coordinates.
2xxx Invert all bond stretch coordinates.
3xxx If the coordinates are GICs generated using the molecular connectivity (See Routine CrdCon), use the input connectivity as is and do not add any new (virtual) bonds by default.
4xxx Default to 0xxx for any case except for 49×2 and 49×3. The option 49×2 means (geom=chkgic for 4902) to skip any default coordinates for the current geometry and use the GICs from a checkpoint file (generated for a different geometry, perhaps). Unlike Geom=Check, Geom=ChkGIC does not use the checkpoint Cartesian coordinates. The option 49×3 (geom=(ChkGIC,AddGIC) or Geom=(ChkGIC,ModRed) for 4903) does the same thing but can also read an additional GIC input to modify the checkpoint GICs.
0xxxxx Do 1xxxxx for large cases with generic GICs and 2xxxxx for anything else.
1xxxxx Optimize the number of GIC primitives for cases when the procedure is implemented.
2xxxxx Do not optimize the number of GIC primitives.
0000000 Default for digit 0 default is 2 (GIC).
1000000 Default digit 0 to 1 if not specified (NoGIC).
2000000    Default digit 0 to 2 if not specified (GIC).

IOp(1/146)

Control of SCVS:

0 Default (03045011).
1 Include forces in virial ratio.
2 Do not include forces in virial ratio.
1x Use Murdoch’s extrapolation.
2x Do not use Murdoch’s extrapolation.
Nxx Apply SCVS when max force on nuclei is below 10-N.
Mxxx The convergence on the virial Eta. Default is 5.
Lxxxx The convergence threshhold on |E| * (2*Eta – 2), where |E| is the magnitude of the kinetic energy is 10-M. Default is 3.
Kxxxxx The initial order of extrapolation is 10L
JJJxxxxxx Maximum of KKK SCVS iterations.

IOp(1/146)

Control of SCVS:

0 Default (03045011).
1 Include forces in virial ratio.
2 Do not include forces in virial ratio.
1x Use Murdoch’s extrapolation.
2x Do not use Murdoch’s extrapolation.
Nxx Apply SCVS when max force on nuclei is below 10-N.
Mxxx The convergence on the virial Eta. Default is 5.
Lxxxx The convergence threshhold on |E| * (2*Eta – 2), where |E| is the magnitude of the kinetic energy is 10-M. Default is 3.
Kxxxxx The initial order of extrapolation is 10L
JJJxxxxxx Maximum of KKK SCVS iterations.

IOp(1/147)

0 Default (2).
1 Symmetrically orthogonalize before ES(X).
2 Do not symmetrically orthogonalize before ES(X).

IOp(1/148)

0 Default (221 except 222 for single differentiation with respect to normal modes).
1 Normal storage of numerical first derivatives.
2 Store numerical first and diagonal second derivatives.
10 Print differences between numerical and analytic quantities.
20 Do not print differences.
N00 Threshold for printing differences is -6-N.

IOp(1/149)

0 Default (zero).
N N*0.01 Hartree/Bohr2

IOp(1/150)

0 Default (1.0)
N 1 + N/100000000

IOp(1/151)

How many vectors with negative curvature to use in downhill step during minimization:

0 Default (3)
-1 None, do regular RFO step.
N Up to N vectors.

IOp(1/152)

0 Default: compute based on number of variables, NStep, etc.
N>0 Make MaxStp at least N.
N<0 Make MaxStp at least -N.

IOp(1/153)

0 Default: Yes.
1 Yes
2 No

IOp(1/154)

Linear angle test during internal coordinate generation.

0 Default (15 degrees, applied to all 3 tests).
-N Threshold N degrees, applied to the angle only.
N Threshold N degrees, applied to all 3 tests.

IOp(1/155)

0 Default (0000000).
N If 0<N<999, do N passes using the overall step scaled at each pass i by a factor of i/N (i=1, N). If N=0, do one full step (like for N=1) and, if it fails, do N=10.
0xxx Do a regular least-squares fit of all internal coordinates to their target values (which can be their initial values).
1xxx Do a partial fitting. Fit the selected internal coordinates to their target values exactly, ignore the remaining ones but keep the Cartesian coordinates at their initial values as much as possible.
2xxx Do 1xxx but preserve the fragments when moving the atoms provided there are two or more fragments as determined from the default connectivity matrix.
0xxxx Do 2xxxx for relaxed energy scans with GICs and do 1xxxx for any other case.
1xxxx Keep the values of dihedral angles and linear bends within the canonical range of [-Pi,Pi] and [0,2Pi], respectively, and print them as such. Remove an extra Pi from the corresponding displacements, when needed. For example, a dihedral angle’s values of 170 degrees and 190 degrees will be converted to 170 and -170, respectively, and the change from 170 to -170 (or 190) degrees will be treated as +20 degrees (not -340). Combinations of pure dihedral angles (or linear bends) (GICs only) are treated by treating individual angles as described above. This has been used for both the old redundant coordinates and the GICs.
2xxxx Keep the values of dihedral angles and linear bends at each optimization point in the same phase with the corresponding angles at the previous point and print them as such. Keep the initial values within their canonical range. For example, the initial value of a dihedral angle changes in (-30)-degree increments from -151 to 179 and then to 149 degrees according to the canonical range. The actual values will be -151, -181, and -211, respectively.
0xxxxx Do 1xxxxx for the GICs that do not depend on the total translations and rotations (e.g., regular bonds and angles with no (frozen or unfrozen) Cartesian atoms) and do 2xxxxx if they depend on such motions (e.g., for Cartesian atoms in terms of explicit Cartesian coordinates, 3A linear bends, rotor-like GICs).
1xxxxx Allow for rigid-body rotations and translations of the QM fragment in the QM:MM ONIOM with GICs (implemented only for a case when some MM parts are frozen; RotQM=.True. in GetNRF) and assume that the current internal coordinates do not depend on the total translations and rotations in any other case when it matters (including non-ONIOM calculations).
2xxxxx Do not allow for rigid-body rotations and translations of the QM fragment (RotQM in GetNRF is always .False.) and assume that the current internal coordinates depend on the total translations and rotations in any other case when it matters (including non-ONIOM calculations).
0xxxxxx Do 1xxxxxx by default instead of 2xxxxxx for any case except for those with generic periodic GICs that involve an extrapolation of internal coordinates (e.g., QSt2, Path=7, etc.) and for those that request GIC symmetrization.
1xxxxxx Use a proper phase (2Pi) for pure angles and some trivial GICs built by default (e.g., XY3-type dihedral GICs) when FixDq needs to be called to correct the corresponding displacement but skip such a treatment for any user-provided generic GIC unless there is an explicit GicPhase input. Note that a pure angle has a phase of 2Pi which means that the values of Alp and Alp+/-2*Pi*n correspond to the same Cartesian geometry of the involved atoms and the corresponding displacement DelAlp should not exceed 2Pi (see FixDq).
2xxxxxx Do 1xxxxxx to treat the periodicity of pure angles and some trivial cases but also call CrRnge for an extra work to determine the proper phase for any non-trivial generic periodic GIC for the use in FixDq to remove an extra phase from the corresponding displacement when needed. The CrRnge subroutine does not override any user-provided GicPhase data.
0xxxxxxx If the rotor-type GICs are requested by Geom=Rotors or by default, build C, P, Q, and S-type GICs using only the MxLFrg closest-to-the-center atoms per each fragment with more than MxLFrg atoms (MxLFrg=50). This is the default.
1xxxxxxx    If the rotor-type GICs are requested by Geom=Rotors or by default, do 0xxxxxxx but ignore the MxLFrg limit.

IOp(1/156)

Automatic generation of internal coordinates.

0 Default (16 if using GICs).
1 Generate bonds, angles, and dihedrals.
2 Generate bonds and angles but no dihedrals.
3 Generate bonds only.
4 Generate no coordinates automatically.
5 Generate Z-Matrix type GICs using opt or geom with gic or addgic and a Z-Matrix provided (GICs only).
6 Generate the Rotor(1) model GICs for a non-rigid (weakly-bound) system of individual fragments (e.g., a water cluster). The fragment info should be provided via the Fragment= specification or via Fragment() in the GIC input section or via the default or user-provided connectivity information. If there are no fragments then default to 1.
7 Do 2 and then 6.
8 Generate a rotation quaternion Qua=(K0,K1,K2,K3) for each fragment where K0, K1, etc. are expressed in terms of the dot-products P.P0, P.Q0, etc., where P, Q, S are built according to the option 6 above and P0, Q0, S0 refer to their values at the initial geometry. Stop with an error message if there are no fragments and, therefore, no PQS GICs to convert.
9 Default to 1 and do NoRotors.
1x Modify the current GICs according to ModelXY3.
2x Modify the current GICs according to ModelAB3.
3x Modify the current GICs according to ModelXY3 and ModelAB3.
4x Modify the current GICs according to ModelXY3-1 (for debugging). Note that ModelXY3 skips the XY3 groups attached to the same atom (e.g., (H3C)2-R or C(CH3)4) as well as some other cases that may not work well but ModelXY3-1 does not skip anything.
9x No modification.
0xx Do not symmetrize GICs (by CrdGiS) by default.
1xx Symmetrize GICs according to the current point group, saving only totally symmetric GICs.
2xx Symmetrize GICs according to the current point group, saving all GICs.
3xx Symmetrize GICs according to the current permutation group.
4xx Symmetrize GICs according to the current permutation-inversion group.
5xx Do 2xx but freeze all the symmetrized combinations except for the totally symmetric ones.
0xxx Do not use 1xxx by default except for IRC=Report with GICs and Opt=GicOneSym.
1xxx Use special settings (NTrRot=-3, SkpSLE) to treat coordinate systems that are incomplete (e.g., when we do optimization using only the fully symmetric block of symmetrized GICs).
0xxxx Do 3xxxx by default. However, the option 2xxxx can be tested if the Eckart conditions on the total translations and rotations are used.
1xxxx Translate and rotate the initial geometry to place the molecular center (XCntr,YCntr,ZCntr) at the origin (0,0,0) and to make the off-diagonal elements of the MofI matrix (X2Cntr,Y2Cntr,Z2Cntr) equal to zero.
2xxxx Translate the center of the initial geometry the origin (0,0,0).
3xxxx Do not translate or rotate the initial geometry.

IOp(1/157)

0 Default, 0.1 maximum element.
N N/1000 for maximum element of step vector.
-N -N/1000 for length of step vector.

IOp(1/158)


IOp(1/159)

Default maximum step in Cartesians during redundant coordinate optimizations.

-1 Unlimited (106 Bohr).
0 Default (3 Bohr unless some special GICs in use, then 1.5).
N N/10 Bohr.

IOp(1/160)

Type of fragment calculation:

0 Default (11).
1 Force use of new ghost atoms in counterpoise.
2 Force use of old ghost atoms in counterpoise.
10 Counterpoise.
20 Fragment guess.
30 Morokuma energy decomposition.
40 XPol.
50 Variational XPol.
60 For testing methods within normal iterations.
80 Excitation energy transfer.
90 Fragments for disjoint ONIOM model systems.
1xxx Do only densities with EET.
2xxx Recover densities from chk for EET.

IOp(1/161)

0 Default (No).
1 Yes.

IOp(1/162)

Frequency of analytic Hessians during IRC corrector cycles.


IOp(1/163)

Copy of external input section from chk file:

0 Default; copy if Geom=AllCheck.
1 Copy regardless.
2 Do not copy.

IOp(1/164)

Read of atomic pair potential.

0 Default; copy from chk if Geom=AllCheck.
1 Read from input.
2 Do not read.
3 Read from chk.

Each pair is given on one line of the form: IA,IB,R0,A,B,ROn,ROff,C(n),C(n-1),…,C(0).

The potential is of the form P(X)*Exp(A*X)*Exp(B*X*X)*Sw(Rab,ROn,ROff).

If A is zero, the exponential is omitted. If B is zero, the Gaussian is omitted, and if ROn is zero, the Stratmann-Scuseria switching function Sw is omitted. P(X) is the polynomial of degree n given by the specified coefficients. n is determined from the # of C’s provided and can be 0 for a constant scale factor.


IOp(1/165)

Convergence of MM microiterations.

0 Default (10x tighter than macro, except 10x for FOSimult with MM included).
N Nx tighter.

IOp(1/166)

0 Default.
NN Save N vectors (default 10 for GEDIIS, 10 for SimOpt).
MMNN Mix up to MM < NN vectors in DIIS when mixing RFO steps. (Default NN).

A negative value requests uses of the Hessian eigenvector basis for the step. This is the default and only choice for GEDIIS TS optimizations.

0 Default = 2

IOp(1/167)

Version of GEDIIS.

0 Default (2).
1 Old.
2 New.
0 default 100
N Save the traj. data to checkpoint file every N steps

IOp(1/168)

GEDIIS switches.

NN Switch from RFO to DIIS on RMS force (10-NN, default 1.d-3).
MM00 Switch toEn-DIIS from RFO-DIIS on RMS step (10-MM, default 2.5 times RFO to DIIS threshold).
LLL0000 Maximum coefficient allowed in RFO-DIIS before space is reduced (LLL/10, default 10.0).
KKK0000000    Maximum coefficient allowed in RFO-DIIS before coefficients are adjusted (KKK/10; default 3.0). The minimum value is -KKK/10 + 1.
0 default (Coord., Momenta,Potential,TVir)
1 dipole moments
10 available charges
100 Electronic Only
1000 Gradients

IOp(1/170)

XXYY    YY: initial condition for coordinates and momenta. XX: initial condition for electron densities
XX01 Read initial Cartesian coordinates and momenta (or velocities) from the input stream. Note that the momenta/velocities must have the same symmetry orientation as the coordinates. The input momenta/velocities are in atomic unit; coordinates have the same unit as the molecular specification part controlled by Units=AU/Ang
XX03 The initial velocities are randomly generated and the initial coordinates are read from the molecule specification. All trajectories have the same initial coordinates. This is the default.
XX04 The initial velocities are generated according to Boltzmann’s distribution at the given temperature. The initial coordinates are read from the molecule specification. All trajectories have the same initial coordinates. It is often useful to start an equilibrium trajectory
XX05 Classical harmonic oscillator approximation. This option require user to provide total energy in kcal/mol after molecule specification. In this option, program will calculate the harmonic frequencies using the input geometry and assume the input geometry is already optimized.
XX06 Orthant sampling. It also requires providing total energy in kcal/mol after molecule specifiction.
XX07 Sampling using quantum harmonic oscillator at vibrational ground state. It also requires frequency calculation using the input geometry.
XX08 Classical sampling for harmonic osicllator (Each mode has its own fixed input energy in kcal/mol)
XX09 Canonical ensemble for a given temeprature T
XX10 Read initial coordinates and momenta from checkpoint file This option is often used to sample snapshots from an equilibrium run.
01YY Generate the electron densities for Ehrenfest
02YY Read the electron densities for Ehrenfest from the option 01XX

IOp(1/171)

0 Default. Same as 2.
1 Yes.
2 No.

IOp(1/172)

0 Default (No).
1 Print if present.

IOp(1/173)

L106: Extra files to differentiate.

-11 Differentiate the files related to ground-state post-SCF 2nd derivatives (Lagrangian, P, and W).
-10 Differentiate the files related to CIS/TD second derivatives (Lagrangian, P, W, and T).
-2 Read two lists, each terminated by a blank line, the first the files to differentiate and the second the files where the numerical derivatives will be stored (0 for items which will not be saved).
-1 Read a list from an input section, terminated by a blank link. The numerical derivatives will be printed but not stored on disk.
N>0 Do file number N, storing derivatives in file 795.

IOp(1/174)

Reading parameters for classical electrostatics and dispersion.

0 Default, 3 if Geom=AllCheck else 2.
1 Read selected parameters for elements from input.
2 Use default parameters.
3 Read user-specified parameters from chk file if present.
4 Read both user-specified and default parameters from chk file if present.

IOp(1/175)

Electronic embedding type:

0 Default (1)
1 ONIOM style.
2 QM/MM style.

IOp(1/176)

Box size used for generating connectivity.

0 Default (8 Bohr).
N N Bohr.

IOp(1/177)

0 Default (10)
N N Microiterations
-N Frozen nuclei
0 default as 1
N N microiteration steps
<0 Electronic only. Equivalent to RT-TDSCF.

IOp(1/178)

0    Default (=2).
1 SCF Energy + <S2>
2 This is an Approximate Projection calculation. The list of spin states is given by the user in the input file. This type of calculation assumes a two-state model and the user must give the two states in the input file, with the high-spin state given first and the low-spin state given second.
3 SCF Energy + Alpha
4 Noodleman. As for option 2, but alpha is always set to the corresponding Clebsh-Gordan cofficient.
5 Locating minimum energy crossing point (MECP). NYI.
0 Default as 2
1 Ignore the frustrated hopping
2 Reflect the momenta along the NAC vector

IOp(1/179)

L106, L127: Use of subprocesses or Linda.

0 Default (11002).
1 Yes.
2 No.
3 Yes, using loop over steps in L106.
4 Yes, using loop over calls to utility in L106.
5 Yes, using Linda.
1x Debug output and save of subprocess files.
1xx Full copy of rwf back and forth.
1xxx Iterate purturbations forward.
2xxx Iterate purturbations backward.

IOp(1/180)

Stopping during subprocess execution, for debugging.

0 Don’t stop.
N Stop after running N subprocesses.

IOp(1/181)

Maximum number of middle iterations during ONIOM-EE:

0 Default (40).
N N.

IOp(1/182)

0 default=500 fs
N N fs

IOp(1/183)

0 do not save density
N save the electron density every N steps. Note the electron density matrices between N steps are discarded.

IOp(1/184)

0 Default (50 for electronic only; 10 for Ehrenfest)
N N steps

IOp(1/185)

0 Default, 10**-7 (see PCMDef)
N 10**-N.

IOp(1/186)

0 Default (50, see PCMDef)
N N.

IOp(1/187)

-1 No PE.
0 Default (4 for Geom=AllCheck, no PE otherwise).
1 Initialize with defaults
2 Recover control parameters from checkpoint file.
3 Same as 2 but also allow for modifications.
4 Read from chk if present.
5 Read from rwf.
9 used in parse and cleared.
N0 Electrostatic interactions model:
2x Fluctuating charges – damped 1/r (Ohno, etc…).
3x Fluctuating charges – damped 1/r intrafragment only.
4x Induced dipoles – Amber 12.
5x Induced dipoles – Amber.
6x Induced dipoles – Thole.
7x Induced dipoles – Groups.
8x Induced dipoles – Amoeba.
N000 Solution method:
0xxx Default (decide on the fly).
1xxx Inversion.
2xxx Iterative conjugate gradient.
3xxx Iterative Jacobi + DIIS.
N0000 Storage of the matrix:
0xxxx Default (yes if it fits).
1xxxx Force in-core matrix.
2xxxx Forbid in-core matrix (force iterative).
3xxxx Forbid in-core matrix (force iterative and FMM).
N00000 Handling of the charge-charge interactions
0xxxxx Default (same as 2)
1xxxxx Do the charge-charge interactions in every ONIOM subcalculation.
2xxxxx Do the charge-charge interactions only in the QM subcalculations.
3xxxxx Do PE electrostatics in MM link.
N000000 Handling of the dipole-dipole and charge-dipole interactions
0xxxxxx Default (same as 2)
1xxxxxx Do the dipole-dipole and charge-dipole interactions in every ONIOM subcalculation.
2xxxxxx Do the dipole-dipole and charge-dipole interactions only in the QM subcalculations.
N0000000 0xxxxxxx Default (No).
1xxxxxxx Include the polarizable sites in the system, i.e. they interact with external field.
2xxxxxxx Exclude the polarizable sites from the system, i.e. they do not interact with external field.
100000000    Use prototype code capable of doing both fluctuating charges and induced dipole (default for models 1-3, not available for Amoeba).

IOp(1/188)

0 Default (5)
N Converge to 10-N

IOp(1/189)

0 Default (-2).
-2 No cutoff.
-1 Hard cutoff.
1 Connectivity-based scaling.
2 York-Karplus switching.
NNNN0 Cutoff range in 1/100s Angstroms.
MMMM00000 Radius for soft cutoffs in 1/100s Angstroms.

IOp(1/190)

0 Default (model dependent).
-2 No cutoff.
-1 Hard cutoff.
1 Thole.
2 York-Karplus switching.
NNNN0 Cutoff range in 1/100s Angstroms.
MMMM00000 Radius for soft cutoffs in 1/100s Angstroms.

IOp(1/191)

0 Default (model dependent).
-2 No cutoff.
-1 Hard cutoff.
1 Thole.
2 York-Karplus switching.
NNNN0 Cutoff range in 1/100s Angstroms.
MMMM00000 Radius for soft cutoffs in 1/100s Angstroms.

IOp(1/192)

0 Default (2, Ohno).
1 Nishimoto-Mataga (1.0).
2 Ohno (2.0).
3 Louwen (3.0).
-NNNN Exponent equal to NNNN/1000.

IOp(1/193)

0 Energy only (default).
1 Energy and gradient.
2 Energy, gradient and Hessian
10 Dipole and Polarizabilities

IOp(1/194)


IOp(1/195)


IOp(1/196)

NN Set print flag to NN.
0xx Default (1)
1xx Include MMPol atoms in interaction with external field.
2xx Do not include MMPol atoms in interaction with external field.

IOp(1/198)

0 Default, copy from chk if Geom=AllCheck.
1 Read from input.
2 Do not read.
3 Read from chk.

IOp(1/199)

1 moving grid.
2 globally fixed grid

IOp(1/200)


IOp(1/201)


IOp(1/202)


IOp(1/203)


IOp(1/204)


IOp(1/205)


IOp(1/206)


IOp(1/207)

3xxxxxxx Read an input section with a list in the format for files=… and pass this to RunExt.

IOp(1/208)

0 Default (2)
1 Travelling
2 Fixed

SideMenu

SideMenu